Show walls
- Width and location of every exterior wall is shown
- Size and location of every exterior column and post is shown
- Width and location of every interior wall is shown: full height, partial height
- Size and location of every operable or demountable wall is shown
- Size and location of every interior column is shown
- Size and location of every wall opening is shown: doors, windows, louvers, vents, cased openings, glazed openings
- Location of all existing construction features to remain are shown
- Location of all existing construction to be demolished is shown
Show interior construction
- Size and location of every floor opening is shown: stairs, elevators, trash chutes, mail chutes, shafts, chases, ramps
- Size and location of every raised or depressed floor condition is shown
- Size and location of every stair run is shown
- Size and location of every furred or recessed area is shown
- Location of every attached wall component is shown: signs, chalkboards, bulletin boards, mirrors
- Door swing or opening direction of every door is shown: swinging, sliding, pocket, overhead
Show exterior construction
- Size and location of every exterior building attachment is shown: stairways, decks, balconies
- Size and location of every exterior stair run is shown
Show related exterior conditions
- Location of every exterior projection below is shown: roofs, trellises
- Location of every exterior projection above is shown: overhangs, soffits
Show related interior conditions above
- Location of every interior skylight and ceiling change above is shown
- Location of every interior soffit and dropped ceiling is shown
- Location of every dropped header at cased openings is shown
Show related interior conditions
- Location of every floor material transition is shown
- Location of edge of floor at every exterior door is shown
- Location of every seismic joint, control joint, expansion joint is shown
- Location of all asbestos abatement areas are shown
- Size and location of every access panel is shown
Show special residential equipment
- All residential bathroom equipment is shown: water closets, bidets, sinks, showers, tubs, vanities, grab bars, recessed medicine cabinets, toilet paper holders
- All residential kitchen equipment is shown: dishwashers, microwaves, range hoods, ovens, cooktops, trash compactors, wall cabinets, base cabinets, countertops, sinks
- All residential laundry room equipment is shown: washers, dryers, shelving, laundry chutes, recessed plumbing connection boxes
- All living room equipment is shown: fireplaces, built-ins
Show special room-related equipment
- All closet equipment is shown: closet poles, shelves, built-in shelving systems
- All janitor closet equipment is shown: floor drains, floor sinks, hose bibbs
- All corridor equipment is shown: fire hose cabinets, electrical cabinets, fire extinguishers
- All utility room equipment is shown: HVAC equipment, fire extinguishers, water heaters, boilers, electrical panels, ladders, transformers
- All stairwell equipment is shown: fire sprinkler risers, handrails, handrail extensions, guardrails, floor identification signs
- All commercial bathroom equipment is shown: toilet partitions, urinal screens
- All exterior deck, balcony equipment is shown: deck drains, guardrails
Show required sign locations
- Every required sign is identified and located: stairs, exits, floor numbers, room numbers, fire-exit requirements
Coordinate with office standards
- Floor plan scale conforms to office standard
- Every item represented by appropriate abbreviation or symbol. See show floor plan notations
- Every graphic symbol conforms to office standard: style, size, location
- Every line symbol and line weight conforms to office standard
- Every item is drawn on appropriate CAD layer, conforming to office standard
Coordinate with other drawings
- Every exterior wall and opening agrees with exterior elevations
- Every interior wall and opening agrees with interior elevations
- All interior casework and equipment agrees with interior elevations
- Every stair run length agrees with stair sections
- Location of every projection below agrees with plan below
- Location of every projection above agrees with plan or roof above
- Location of every skylight agrees with roof plan
- Every wall and wall opening agrees with structural drawings
- Every floor opening agrees with structural drawings
- Location of every seismic joint, control joint, expansion joint agrees with structural drawings
- Every floor slope to drain agrees with structural drawings
- Every raised or depressed floor slab condition agrees with structural drawings
- Open doors don't interfere with light switch locations
- Floor drain locations agree with plumbing drawings
- Floor drain locations don't conflict with structural members or mechanical equipment
Coordinate firewalls
- Firestopping locations agree with firewall locations
- Fire damper locations agree with firewall locations
- Fire doors and windows agree with firewall locations
Comments
- This is an incremental task. It's usually started in DD phase and completed in CD phase.
- This checklist will be expanded to include additional building types later.
- Most coordination work can be done by laying one drawing over another.
- Coordination with building codes will be covered as a separate task.
Search For More Information
Printer-Friendly Version
Click here for a version of this page that's more suitable for printing. After printing, click the back-arrow of your browser to return to the original format with an index alongside.
Feedback Wanted
Comments or suggestions? Please email dennis@architecturalpractices.com. For more information, see contact us.
Document Information
- Original post: January 22, 2004, written by Dennis V. O'Neill.
- Last revision: April 21, 2004.
- Thanks for comments from: Marvin Johnson, Beverly Prior Architects
Copyright 2004 - 2007 Dennis V. O'Neill